{"id":429,"date":"2015-01-09T12:46:50","date_gmt":"2015-01-09T12:46:50","guid":{"rendered":"http:\/\/www.tecnofund.com.br\/ing\/?page_id=429"},"modified":"2015-01-30T14:08:50","modified_gmt":"2015-01-30T14:08:50","slug":"per","status":"publish","type":"page","link":"http:\/\/www.tecnofund.com.br\/ing\/per\/","title":{"rendered":"PER"},"content":{"rendered":"<p>[et_pb_section fullwidth=&#8221;on&#8221; specialty=&#8221;off&#8221; background_color=&#8221;#edce21&#8243; inner_shadow=&#8221;off&#8221; parallax=&#8221;off&#8221; parallax_method=&#8221;css&#8221;][et_pb_fullwidth_header admin_label=&#8221;Fullwidth Header&#8221; title=&#8221;Foundry Equipment&#8221; subhead=&#8221;Test Instruments for Moulding and Core Sands&#8221; background_layout=&#8221;light&#8221; text_orientation=&#8221;left&#8221; \/][\/et_pb_section][et_pb_section fullwidth=&#8221;off&#8221; specialty=&#8221;on&#8221; background_color=&#8221;#f4f4f4&#8243; inner_shadow=&#8221;off&#8221; parallax=&#8221;off&#8221; parallax_method=&#8221;css&#8221;][et_pb_column type=&#8221;3_4&#8243; specialty_columns=&#8221;3&#8243;][et_pb_row_inner][et_pb_column_inner type=&#8221;1_2&#8243;][et_pb_image admin_label=&#8221;PER&#8221; show_in_lightbox=&#8221;on&#8221; url_new_window=&#8221;off&#8221; animation=&#8221;left&#8221; src=&#8221;http:\/\/www.tecnofund.com.br\/ing\/wp-content\/uploads\/2015\/01\/per.jpg&#8221; \/][\/et_pb_column_inner][et_pb_column_inner type=&#8221;1_2&#8243;][et_pb_text admin_label=&#8221;Titulo&#8221; background_layout=&#8221;light&#8221; text_orientation=&#8221;left&#8221;]<\/p>\n<h2><span style=\"color: #ff6600;\"><strong>Model PER<\/strong><\/span><\/h2>\n<p>[\/et_pb_text][et_pb_text admin_label=&#8221;Descri\u00e7\u00e3o&#8221; background_layout=&#8221;light&#8221; text_orientation=&#8221;left&#8221;]<\/p>\n<h4><strong>DIGITAL\u00a0PERMMETER<\/strong><\/h4>\n<p>For determination the permeability of\u00a0clay and\/or chemically bonded sand specimens<\/p>\n<p><strong>SPECIFICATIONS<\/strong><\/p>\n<ul>\n<li>Measuring range: 0 &#8211; 999 cm4\/g.min. (AFS)<\/li>\n<li>Range resolution: 0,1 cm4\/g.min. (AFS)<\/li>\n<li>Uses Metric ou AFS specimens<\/li>\n<li>Calibration standard included<\/li>\n<li>Power requirements: 230 V \/ 50-60 Hz<\/li>\n<li>Compressed air required: 2 bar (28 psi)<\/li>\n<li>Weight: 26 kg (57 lb)<\/li>\n<\/ul>\n<p>[\/et_pb_text][\/et_pb_column_inner][\/et_pb_row_inner][et_pb_row_inner][et_pb_column_inner type=&#8221;4_4&#8243;][et_pb_text admin_label=&#8221;Tabela&#8221; background_layout=&#8221;light&#8221; text_orientation=&#8221;left&#8221;]<\/p>\n<table class=\"tabela\" border=\"1\" width=\"680\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr class=\"tabelaCopy2\">\n<td class=\"verdana11preto\" rowspan=\"2\" align=\"center\" bgcolor=\"#C6E2F0\"><strong>PROCESS OF SAND<\/strong><\/td>\n<td class=\"verdana11preto\" rowspan=\"2\" align=\"center\" bgcolor=\"#C6E2F0\"><strong>MOLD AND CORE SAND TESTS<\/strong><\/td>\n<td class=\"verdana11preto\" colspan=\"3\" align=\"center\" bgcolor=\"#C6E2F0\"><strong>EQUIPMENTS (MODELS)<\/strong><\/td>\n<\/tr>\n<tr class=\"tabelaCopy2\">\n<td class=\"verdana11preto\" align=\"center\" bgcolor=\"#C6E2F0\"><strong>PERFORMS THE TEST<\/strong><\/td>\n<td class=\"verdana11preto\" align=\"center\" bgcolor=\"#C6E2F0\"><strong>ACCESSORIES AUXILIARY<\/strong><\/td>\n<td class=\"verdana11preto\" align=\"center\" bgcolor=\"#C6E2F0\"><strong>ESPECIMEN PREPARATION<\/strong><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" align=\"center\" bgcolor=\"#FFECB3\"><strong>CLAY BONDED MOULDING SANDS<\/strong><\/td>\n<td align=\"center\" bgcolor=\"#FFECB3\">PERMEABILITY<\/td>\n<td align=\"center\" bgcolor=\"#FFECB3\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/per\/\">PER<\/a><\/td>\n<td align=\"center\" bgcolor=\"#FFECB3\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/ecp\/\">ECP<\/a><\/td>\n<td align=\"center\" bgcolor=\"#FFECB3\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/mm-2\/\">MM<\/a><\/td>\n<\/tr>\n<tr>\n<td align=\"center\" bgcolor=\"#FFECB3\">MOLD PERMEABILITY<\/td>\n<td align=\"center\" bgcolor=\"#FFECB3\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/per\/\">PER<\/a><\/td>\n<td align=\"center\" bgcolor=\"#FFECB3\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/ap01\/\">AP01<\/a><\/td>\n<td align=\"center\" bgcolor=\"#FFECB3\">&#8211;<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" bgcolor=\"#FFDDDD\"><strong>UNBONDED SANDS<\/strong><\/td>\n<td align=\"center\" bgcolor=\"#FFDDDD\">PERMEABILITY<\/td>\n<td align=\"center\" bgcolor=\"#FFDDDD\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/per\/\">PER<\/a><\/td>\n<td align=\"center\" bgcolor=\"#FFDDDD\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/ap03\/\">AP03 <\/a>and\u00a0<a href=\"http:\/\/www.tecnofund.com.br\/ing\/ecp\/\">ECP<\/a><\/td>\n<td align=\"center\" bgcolor=\"#FFDDDD\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/mm-2\/\">MM<\/a><\/td>\n<\/tr>\n<tr>\n<td align=\"center\" bgcolor=\"#D2E9BC\"><strong>CHEMICALLY-BONDED SELF-SETTING SANDS<\/strong><\/td>\n<td align=\"center\" bgcolor=\"#D2E9BC\">CORE PERMEABILITY<\/td>\n<td align=\"center\" bgcolor=\"#D2E9BC\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/per\/\">PER<\/a><\/td>\n<td align=\"center\" bgcolor=\"#D2E9BC\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/ap01\/\">AP01<\/a> <span class=\"texto\">or<\/span>\u00a0<a href=\"http:\/\/www.tecnofund.com.br\/ing\/ap04\/\">AP04<\/a><\/td>\n<td align=\"center\" bgcolor=\"#D2E9BC\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/mm-2\/\">MM<\/a><\/td>\n<\/tr>\n<tr>\n<td align=\"center\" bgcolor=\"#E6E6FF\"><strong>HOT-BOX MIXES SANDS<\/strong><\/td>\n<td align=\"center\" bgcolor=\"#E6E6FF\">CORE PERMEABILITY<\/td>\n<td align=\"center\" bgcolor=\"#E6E6FF\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/per\/\">PER<\/a><\/td>\n<td align=\"center\" bgcolor=\"#E6E6FF\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/ap02\/\">AP02<\/a><\/td>\n<td align=\"center\" bgcolor=\"#E6E6FF\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/msl-hb\/\">MSL HB<\/a>\u00a0<span class=\"texto\">or<\/span>\u00a0<a href=\"http:\/\/www.tecnofund.com.br\/ing\/msl-hc\/\">HC<\/a><\/td>\n<\/tr>\n<tr bgcolor=\"#FFE6E6\">\n<td align=\"center\" bgcolor=\"#FFE6E6\"><strong>COLD BOX MIXES SANDS<\/strong><\/td>\n<td align=\"center\" bgcolor=\"#FFE6E6\">CORE PERMEABILITY<\/td>\n<td align=\"center\" bgcolor=\"#FFE6E6\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/per\/\">PER<\/a><\/td>\n<td align=\"center\" bgcolor=\"#FFE6E6\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/ap02\/\">AP02<\/a><\/td>\n<td align=\"center\" bgcolor=\"#FFE6E6\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/msl-cb\/\">MSL CB<\/a>\u00a0<span class=\"texto\">or<\/span>\u00a0<a href=\"http:\/\/www.tecnofund.com.br\/ing\/msl-hc\/\">HC<\/a><\/td>\n<\/tr>\n<tr>\n<td align=\"center\" bgcolor=\"#FFE2C6\"><strong>SHELL MOLDING SANDS<\/strong><\/td>\n<td align=\"center\" bgcolor=\"#FFE2C6\">CORE PERMEABILITY<\/td>\n<td align=\"center\" bgcolor=\"#FFE2C6\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/per\/\">PER<\/a><\/td>\n<td align=\"center\" bgcolor=\"#FFE2C6\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/ap02\/\">AP02<\/a><\/td>\n<td align=\"center\" bgcolor=\"#FFE2C6\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/am05\/\">AM05 p<\/a><\/td>\n<\/tr>\n<tr bgcolor=\"#CCCCCC\">\n<td align=\"center\" bgcolor=\"#DADADA\"><strong>GAS-CURED MOLDING SANDS<\/strong><\/td>\n<td align=\"center\" bgcolor=\"#DADADA\">CORE PERMEABILITY<\/td>\n<td align=\"center\" bgcolor=\"#DADADA\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/per\/\">PER<\/a><\/td>\n<td align=\"center\" bgcolor=\"#DADADA\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/ap04\/\">AP04<\/a><\/td>\n<td align=\"center\" bgcolor=\"#DADADA\"><span class=\"texto\"><a href=\"http:\/\/www.tecnofund.com.br\/ing\/agcp\/\">AGCP<\/a>\u00a0and<\/span>\u00a0<a href=\"http:\/\/www.tecnofund.com.br\/ing\/mm-2\/\">MM<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/et_pb_text][\/et_pb_column_inner][\/et_pb_row_inner][\/et_pb_column][et_pb_column type=&#8221;1_4&#8243;][et_pb_sidebar admin_label=&#8221;Sidebar&#8221; orientation=&#8221;right&#8221; area=&#8221;sidebar-1&#8243; background_layout=&#8221;light&#8221; \/][\/et_pb_column][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Model PER DIGITAL\u00a0PERMMETER For determination the permeability of\u00a0clay and\/or chemically bonded sand specimens SPECIFICATIONS Measuring range: 0 &#8211; 999 cm4\/g.min. (AFS) Range resolution: 0,1 cm4\/g.min. (AFS) Uses Metric ou AFS specimens Calibration standard included Power requirements: 230 V \/ 50-60 Hz Compressed air required: 2 bar (28 psi) Weight: 26 kg (57 lb) PROCESS OF [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"open","ping_status":"open","template":"","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"class_list":["post-429","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"http:\/\/www.tecnofund.com.br\/ing\/wp-json\/wp\/v2\/pages\/429","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.tecnofund.com.br\/ing\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/www.tecnofund.com.br\/ing\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/www.tecnofund.com.br\/ing\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.tecnofund.com.br\/ing\/wp-json\/wp\/v2\/comments?post=429"}],"version-history":[{"count":6,"href":"http:\/\/www.tecnofund.com.br\/ing\/wp-json\/wp\/v2\/pages\/429\/revisions"}],"predecessor-version":[{"id":1006,"href":"http:\/\/www.tecnofund.com.br\/ing\/wp-json\/wp\/v2\/pages\/429\/revisions\/1006"}],"wp:attachment":[{"href":"http:\/\/www.tecnofund.com.br\/ing\/wp-json\/wp\/v2\/media?parent=429"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}